  • ACL Reconstruction System Instrument Set
  • ACL Reconstruction System Instrument Set
  • ACL Reconstruction System Instrument Set
  • ACL Reconstruction System Instrument Set
ACL Reconstruction System Instrument Set

ACL Reconstruction System Instrument Set

Rs 94,500  / SetGet Best Price

Minimum Order Quantity: 5 Set

Product Brochure

BrandSAFEX INC
MaterialAluminium and Stainless Steel
Box MaterialAluminum
Instruments MateirialStainless Steel
Country of OriginMade in India
ACL Reconstruction System Instrument SetSAFEX INC "ACL Reconstruction System Instrument Set" refers to a collection of surgical instruments specifically designed for performing ACL (Anterior Cruciate Ligament) reconstruction surgery.

Additional Information:

  • Item Code: ACL-PCL-1400
  • Production Capacity: 100
  • Delivery Time: Quick Delivery
  • Packaging Details: Poly

View Complete details

get quote request a call back
  • Acl Pcl Instrument Set Arthroscopy Instruments
  • Acl Pcl Instrument Set Arthroscopy Instruments
  • Acl Pcl Instrument Set Arthroscopy Instruments
Acl Pcl Instrument Set Arthroscopy Instruments

Acl Pcl Instrument Set Arthroscopy Instruments

Rs 93,500  / SetGet Best Price

Minimum Order Quantity: 1 Set

Product Brochure

BrandSAFEX INC
MaterialHigh quality SS and Aluminum
DesignInternational Standard
ColorSilver
Country of OriginMade in India

Anterior Cruciate Ligament
SAFEX INCs ACL (Anterior Cruciate Ligament) and PCL (Posterior Cruciate Ligament) Instrument Set is a collection of specialized surgical instruments used in orthopedic surgery to diagnose and treat injuries to the anterior and posterior cruciate ligaments in the knee joint



Additional Information:

  • Item Code: ACL-PCL1700
  • Production Capacity: 100 sets
  • Delivery Time: Quick
  • Packaging Details: Poly

View Complete details

get quote request a call back
  • ACL Reconstruction System
  • ACL Reconstruction System
  • ACL Reconstruction System
ACL Reconstruction System

ACL Reconstruction System

Rs 80,000  / SetGet Best Price

Minimum Order Quantity: 25 Set

Product Brochure

BrandSafex Inc
MaterialAluminium, Stainless Steel, etc
Usage/ApplicationACL PCL Arthroscope Surgery
Packaging TypeBox
Country of OriginMade in India

ACL Reconstruction System
BrandSAFEX INCCountry of OriginMade in IndiaUsageHospitalPackageIndividualColourUniversal



Additional Information:

  • Item Code: ACL-PCL1100
  • Delivery Time: 15 Days

View Complete details

get quote request a call back
  • Acl Pcl Jig
  • Acl Pcl Jig
  • Acl Pcl Jig
Acl Pcl Jig

Acl Pcl Jig

Rs 25,000  / PieceGet Best Price

Minimum Order Quantity: 10 Piece

BrandSAFEX INCs
MaterialTitanium
ColorGolden
SizeUniversal
ApplicationArthrosopy
Country of OriginMade in India
ACL PCL Reconstruction Jig

In orthopedic surgery, particularly in knee surgery, ACL (Anterior Cruciate Ligament) and PCL (Posterior Cruciate Ligament) jigs are specialized surgical instruments used to guide the placement of tunnels during ligament reconstruction procedures. Here's a brief overview of each:

  1. ACL Jig (Anterior Cruciate Ligament Jig):

    • An ACL jig is a surgical tool used to accurately position and drill tunnels in the femur and tibia to reconstruct the anterior cruciate ligament of the knee.
    • It typically consists of a guide with slots or holes that allow the surgeon to position the jig precisely over the anatomical landmarks where the tunnels need to be drilled.
    • The jig helps ensure the correct placement and angle of the tunnels, which is crucial for restoring stability and function to the knee joint.
  2. PCL Jig (Posterior Cruciate Ligament Jig):

    • Similarly, a PCL jig is used for reconstructing the posterior cruciate ligament of the knee.
    • It assists the surgeon in accurately placing and drilling tunnels in the femur and tibia to recreate the PCL.
    • Like the ACL jig, the PCL jig helps achieve proper tunnel placement and angle, which is essential for restoring normal knee function and stability.

Both ACL and PCL jigs are designed to facilitate precise and reproducible tunnel placement, which is critical for the success of ligament reconstruction surgeries. These jigs come in various designs and configurations to accommodate different surgical techniques and patient anatomy. Surgeons often select the appropriate jig based on factors such as the specific surgical approach, patient characteristics, and personal preference.



Additional Information:

  • Item Code: SFI-ACL1500
  • Production Capacity: 100
  • Delivery Time: Quick
  • Packaging Details: Poly

View Complete details

get quote request a call back
  • Acl Jig Tibial Target Guide
  • Acl Jig Tibial Target Guide
  • Acl Jig Tibial Target Guide
  • Acl Jig Tibial Target Guide
Acl Jig Tibial Target Guide

Acl Jig Tibial Target Guide

Rs 9,900  / PieceGet Best Price

Minimum Order Quantity: 5 Piece

BrandSAFEX INCs
ColorGolden
SizeUp to 60 mm screw length
WeightStandard
ApplicationArthroscopy
Country of OriginMade in India

An ACL (Anterior Cruciate Ligament) jig tibial target guide is a specialized surgical tool used in ACL reconstruction procedures to assist in accurately drilling tunnels in the tibia (shinbone) for graft placement. ACL reconstruction is a surgical procedure performed to repair a torn ACL, a common knee ligament injury, by replacing the damaged ligament with a graft.

The ACL jig tibial target guide helps the surgeon precisely position and angle the drill to create tunnels in the tibia at the correct location and trajectory to accommodate the ACL graft. Here are some key features and functions of an ACL jig tibial target guide:

  1. Alignment Guides: The jig includes alignment guides or markers that help the surgeon align the guide accurately with anatomical landmarks on the tibia, such as the tibial tubercle or the center of the ACL footprint.

  2. Adjustable Angles: The jig may have adjustable angles or settings to allow for variations in patient anatomy and surgical technique. This ensures that the drill is positioned at the optimal angle to create tunnels that match the natural alignment of the knee joint.

  3. Stability and Fixation: The jig is designed to provide stability and fixation to maintain the desired position during drilling. It may feature clamps, pins, or other fixation mechanisms to secure the jig to the tibia and prevent movement during the procedure.

  4. Targeting System: The target guide component of the jig provides a visual reference or target point for the surgeon to aim the drill. This helps ensure that the tunnels are created at the correct depth and trajectory to accommodate the ACL graft.

  5. Compatibility: ACL jig tibial target guides are designed to be compatible with various surgical instruments and techniques used in ACL reconstruction procedures, allowing for seamless integration into the surgical workflow.

  6. Sterilization: The jig is made from materials that can be sterilized using standard sterilization methods, such as autoclaving, to ensure aseptic conditions in the operating room.



Additional Information:

  • Item Code: ACL-PCL1504
  • Production Capacity: 100
  • Delivery Time: Quick
  • Packaging Details: Poly Pack

View Complete details

get quote request a call back
  • ACL Graft Sizer With scale acl pcl instruments
  • ACL Graft Sizer With scale acl pcl instruments
  • ACL Graft Sizer With scale acl pcl instruments
ACL Graft Sizer With scale acl pcl instruments

ACL Graft Sizer With scale acl pcl instruments

Rs 4,450  / PieceGet Best Price

Minimum Order Quantity: 1 Piece

BrandSAFEX INCs
MaterialAluminium
ColorBlue
SizeStandard
Country of OriginMade in India

ACL and PCL graft sizers
SAFEX INCs ACL (Anterior Cruciate Ligament) and PCL (Posterior Cruciate Ligament) graft sizers with scales are specialized surgical instruments used in ACL and PCL reconstruction procedures to accurately measure the diameter of the graft tissue and determine the appropriate size for graft preparation. These instruments are essential for ensuring a proper fit and tensioning of the graft during surgery. Here are some key features and functions of ACL and PCL graft sizers with scales:

  1. Measurement Scale: The graft sizer features a measurement scale or markings along its length, typically in millimeters or inches, allowing the surgeon to measure the diameter of the graft tissue precisely.

  2. Multiple Sizes: ACL and PCL graft sizers are available in various sizes to accommodate different graft diameters and patient anatomies. They may come in single-size or adjustable models to meet the specific requirements of the surgical procedure.

  3. Open-ended Design: The graft sizer typically has an open-ended design, allowing the surgeon to slide the graft tissue through the sizer and accurately assess its size without compressing or distorting the tissue.

  4. Biocompatible Material: Graft sizers are made from biocompatible materials such as stainless steel or medical-grade plastic to ensure compatibility with surgical procedures and patient safety. These materials can be sterilized using standard sterilization methods to maintain aseptic conditions in the operating room.

  5. Markings for Graft Length: Some graft sizers may also feature markings or indicators to measure the length of the graft tissue, helping the surgeon determine the appropriate length for graft preparation and fixation.

  6. Compatibility with Surgical Techniques: ACL and PCL graft sizers are designed to be compatible with various surgical techniques and instruments used in ACL and PCL reconstruction procedures, allowing for seamless integration into the surgical workflow.

  7. Ease of Use: Graft sizers are designed for ease of use, with ergonomic handles or grips that provide comfort and control during surgery. They are intuitive to operate and allow for quick and accurate measurement of graft size.



Additional Information:

  • Item Code: ACL-PCL1531
  • Production Capacity: 500
  • Delivery Time: Quick
  • Packaging Details: Poly Pack

View Complete details

get quote request a call back

Arthroscopy Knot Pusher

Rs 9,000  / PieceGet Best Price

Arthroscopy Knot Pusher
Safex Inc arthroscopy knot pusher is a specialized surgical instrument used in arthroscopic surgery to assist in tying and securing knots in sutures. Arthroscopic procedures, which involve minimally invasive techniques to access and operate within joints such as the knee, shoulder, or hip, often require the use of sutures to repair or reconstruct damaged soft tissues, such as ligaments or tendons.

Here are some key features and functions of an arthroscopy knot pusher:

  1. Design: Arthroscopy knot pushers typically have a long, slender shaft with a handle at one end and a blunt or rounded tip at the other. The shaft may be straight or curved to facilitate access to different areas within the joint.

  2. Pushing Knots: The primary function of the knot pusher is to assist in pushing and tightening knots in sutures during arthroscopic procedures. After the surgeon has tied a knot using arthroscopic knot-tying techniques, the knot pusher is used to push the knot down into the desired position and secure it firmly against the tissue.

  3. Gentle Handling: The blunt or rounded tip of the knot pusher is designed to minimize the risk of damaging delicate tissues or causing injury during knot manipulation. It allows the surgeon to exert gentle pressure on the knot without puncturing or tearing surrounding structures.

  4. Controlled Manipulation: Arthroscopy knot pushers provide the surgeon with precise control and manipulation during knot tying and tightening. The ergonomic handle allows for comfortable grip and maneuverability, enabling the surgeon to perform intricate tasks with accuracy and efficiency.

  5. Compatibility with Arthroscopic Techniques: Arthroscopy knot pushers are specifically designed for use in arthroscopic surgery, where limited space and visibility pose challenges to traditional knot-tying methods. These instruments are engineered to be compatible with arthroscopic portals and instruments, allowing for seamless integration into the surgical workflow.

  6. Variety of Sizes and Configurations: Arthroscopy knot pushers come in various sizes and configurations to accommodate different surgical techniques, joint anatomy, and suture materials. Surgeons can choose from straight or curved shafts, as well as different lengths and diameters, to suit their specific procedural needs.

  7. Sterilization Compatibility: Like all surgical instruments, arthroscopy knot pushers are made from high-quality, sterilizable materials such as stainless steel or titanium. They can be sterilized using standard methods such as autoclaving or ethylene oxide (ETO) sterilization to ensure their safety and cleanliness for use in the operating room.

View Complete details

get quote request a call back

Safex Inc ACL Femoral Reamer For Anterior Cruciate Ligament

Rs 2,950  / PieceGet Best Price

An ACL (Anterior Cruciate Ligament) femoral reamer is a specialized surgical instrument used in ACL reconstruction surgery. ACL reconstruction is a procedure performed to replace a torn or damaged anterior cruciate ligament in the knee with a graft, typically harvested from the patient's own tissue or from a donor.

Here are some key features and functions of an ACL femoral reamer:

  1. Design: The ACL femoral reamer typically consists of a long, cylindrical shaft with a cutting head at one end. The cutting head is designed to remove bone and create a tunnel in the femur bone that matches the size and orientation of the ACL graft.

  2. Sizing Options: ACL femoral reamers come in various sizes to accommodate different patient anatomies and surgical techniques. The size of the reamer determines the diameter of the femoral tunnel created during surgery, which must be appropriately sized to ensure optimal graft fixation and stability.

  3. Cutting Mechanism: The cutting head of the femoral reamer may feature sharp cutting edges or blades that rotate to remove bone material as the reamer is advanced into the femur. Some reamers may also have fluted or helical designs to facilitate bone removal and prevent clogging or binding during the procedure.

  4. Guided Placement: ACL femoral reamers are often used in conjunction with specialized instrumentation, such as alignment guides or aiming devices, to ensure accurate placement and orientation of the femoral tunnel. These guides help the surgeon position the reamer at the desired location and angle within the femur to achieve optimal graft placement.

  5. Compatibility with Graft Fixation: The size and orientation of the femoral tunnel created by the reamer must be compatible with the selected graft fixation method. Common methods of graft fixation include interference screws, cortical fixation devices, or suspensory fixation systems, which require specific tunnel dimensions for secure graft fixation.

  6. Sterilization Compatibility: ACL femoral reamers are typically made from high-quality, sterilizable materials such as stainless steel or medical-grade alloys. They can be sterilized using standard methods such as autoclaving or ethylene oxide (ETO) sterilization to ensure their safety and cleanliness for use in the operating room.

View Complete details

get quote request a call back

Safex Inc Femoral Aimer

Rs 1,950  / PieceGet Best Price

ACL femoral reamer for Anterior Cruciate Ligament
An ACL (Anterior Cruciate Ligament) femoral reamer is a specialized surgical instrument used in ACL reconstruction surgery. ACL reconstruction is a procedure performed to replace a torn or damaged anterior cruciate ligament in the knee with a graft, typically harvested from the patient's own tissue or from a donor.

Here are some key features and functions of an ACL femoral reamer:

  1. Design: The ACL femoral reamer typically consists of a long, cylindrical shaft with a cutting head at one end. The cutting head is designed to remove bone and create a tunnel in the femur bone that matches the size and orientation of the ACL graft.

  2. Sizing Options: ACL femoral reamers come in various sizes to accommodate different patient anatomies and surgical techniques. The size of the reamer determines the diameter of the femoral tunnel created during surgery, which must be appropriately sized to ensure optimal graft fixation and stability.

  3. Cutting Mechanism: The cutting head of the femoral reamer may feature sharp cutting edges or blades that rotate to remove bone material as the reamer is advanced into the femur. Some reamers may also have fluted or helical designs to facilitate bone removal and prevent clogging or binding during the procedure.

  4. Guided Placement: ACL femoral reamers are often used in conjunction with specialized instrumentation, such as alignment guides or aiming devices, to ensure accurate placement and orientation of the femoral tunnel. These guides help the surgeon position the reamer at the desired location and angle within the femur to achieve optimal graft placement.

  5. Compatibility with Graft Fixation: The size and orientation of the femoral tunnel created by the reamer must be compatible with the selected graft fixation method. Common methods of graft fixation include interference screws, cortical fixation devices, or suspensory fixation systems, which require specific tunnel dimensions for secure graft fixation.

  6. Sterilization Compatibility: ACL femoral reamers are typically made from high-quality, sterilizable materials such as stainless steel or medical-grade alloys. They can be sterilized using standard methods such as autoclaving or ethylene oxide (ETO) sterilization to ensure their safety and cleanliness for use in the operating room.

View Complete details

get quote request a call back

Safex Inc Arthroscopic Scissors

Rs 3,450  / PieceGet Best Price

Minimum Order Quantity: 10 Piece

Safex Inc Arthroscopic scissors
Arthroscopic scissors are surgical instruments used in arthroscopic procedures to cut and trim soft tissues within the joint. Arthroscopic surgery, also known as arthroscopy, is a minimally invasive surgical technique that allows orthopedic surgeons to visualize, diagnose, and treat various joint conditions using a small camera (arthroscope) and specialized instruments inserted through small incisions in the skin.
Here are some key features and aspects of arthroscopic scissors:

Design: Arthroscopic scissors have a slender, elongated design with sharp blades at the distal end. The blades may be straight, curved, or angled to facilitate access to different areas of the joint and to accommodate various surgical techniques.

Single-Action vs. Double-Action: Arthroscopic scissors may be single-action or double-action instruments. Single-action scissors have blades that open and close with each squeeze of the handles, while double-action scissors have a mechanism that allows the blades to open independently of the handle movement, reducing hand fatigue and providing more precise control.

Blade Configuration: Arthroscopic scissors blades may be serrated, smooth, or combination (with one serrated and one smooth blade). The choice of blade configuration depends on the type of tissue being cut and the surgeon's preference for cutting efficiency and tissue handling.

Length and Size: Arthroscopic scissors come in various lengths and sizes to accommodate different surgical needs and anatomical considerations. Longer scissors may provide better reach and access to deep or hard-to-reach areas of the joint, while shorter scissors may offer better maneuverability and control in tight spaces.

Jaw Opening Width: The width of the scissor's jaw opening determines the maximum thickness of tissue that can be cut effectively. Surgeons may choose scissors with wider jaw openings for cutting thicker tissues or with narrower jaw openings for more delicate dissection.

Material and Construction: Arthroscopic scissors are typically made from high-quality, surgical-grade stainless steel or titanium alloy for durability, corrosion resistance, and biocompatibility. The handles may be coated with non-slip material or ergonomic designs to improve grip and control during surgery.

Sterilization Compatibility: Arthroscopic scissors must be sterilized before each use to prevent infection and cross-contamination. They are compatible with standard sterilization methods such as autoclaving, ethylene oxide (ETO) sterilization, or chemical disinfection.

Applications: Arthroscopic scissors are used in a wide range of orthopedic procedures, including meniscal repair, ligament reconstruction, synovectomy, debridement of damaged tissues, and removal of loose bodies or adhesions within the joint. They allow surgeons to perform precise tissue cutting and shaping while minimizing trauma to surrounding structures

View Complete details

get quote request a call back

Safex Inc Shoulder Arthroscopy Instruments Set

Rs 90,000  / PieceGet Best Price

Arthroscopy instruments set
Safex Inc arthroscopy instruments set typically includes a range of specialized tools and devices used in arthroscopic surgery, a minimally invasive surgical technique used to diagnose and treat joint problems. These instruments are specifically designed to access and operate within the joint space through small incisions, allowing surgeons to visualize and perform procedures without the need for open surgery. While the exact contents of an arthroscopy instruments set may vary depending on the manufacturer and surgical procedure, here are some common instruments that may be included:

  1. Arthroscope: A small camera device connected to a light source and video monitor, used to visualize the interior of the joint. Arthroscopes come in various diameters and angles to accommodate different joints and viewing angles.

  2. Cannulas: Hollow tubes inserted into the joint space to maintain the working area and allow the passage of other instruments. Cannulas come in various sizes and configurations, including straight, curved, and angled designs.

  3. Surgical Probes and Hooks: Instruments used for probing and manipulating tissues within the joint, such as identifying and repairing damaged structures like ligaments, tendons, or cartilage.

  4. Graspers and Forceps: Instruments with serrated jaws used to grasp and manipulate tissues during surgery, allowing surgeons to perform precise movements and procedures.

  5. Scissors and Shavers: Cutting instruments used to trim or remove damaged tissue, cartilage, or bone within the joint. Scissors may have straight or curved blades, while shavers use rotating blades to remove tissue.

  6. Suture Passers and Anchors: Devices used to pass sutures through tissues and secure them in place for ligament or tendon repair. Suture anchors are implanted into bone to anchor sutures for tissue fixation.

  7. Probes and Hooks: Instruments used to assess the integrity of tissues, probe for abnormalities, and manipulate structures within the joint space.

  8. Rongeurs and Punches: Cutting instruments used to remove bone or cartilage fragments, smooth rough edges, or create access points within the joint.

  9. Dilators and Retractors: Instruments used to expand the joint space and provide access for other instruments. Dilators gently enlarge the incision, while retractors hold tissues aside to maintain visibility.

  10. Fluid Management System: Equipment for controlling irrigation and suction within the joint space, ensuring optimal visualization and a clear operating field during surgery.

  11. Sterilization Trays and Accessories: Containers and accessories for sterilizing and organizing the instruments before and after use, maintaining a sterile environment in the operating room.

View Complete details

get quote request a call back

Safex Inc Tendon Stripper Open

Rs 4,500  / PieceGet Best Price

Open tendon stripper
An open tendon stripper is a surgical instrument used in orthopedic procedures to facilitate the removal of tendons or tendon remnants from bone tunnels or fixation devices during tendon repair surgeries. Unlike closed tendon strippers, which are designed for minimally invasive or arthroscopic procedures with limited access to the surgical site, open tendon strippers are used in traditional open surgical approaches where the surgical field is fully exposed.

Here are some key features and characteristics of an open tendon stripper:

  1. Design: An open tendon stripper typically consists of a long, slender shaft with a curved or angled tip. The tip may have a blunt or rounded edge to avoid damaging surrounding tissues during tendon manipulation.

  2. Size: Open tendon strippers come in various sizes to accommodate different tendon sizes and surgical applications. The size of the instrument should be selected based on the specific anatomical location and the diameter of the tendon being manipulated.

  3. Blade: The working end of the open tendon stripper may have a small, sharp blade or cutting edge designed to dissect and separate the tendon from surrounding tissues or fixation devices. The blade is usually retractable or protected to minimize the risk of accidental injury to surrounding structures.

  4. Handle: The handle of an open tendon stripper is typically ergonomic and easy to grip, allowing the surgeon to manipulate the instrument with precision and control. The handle may feature ridges, grooves, or textured surfaces to enhance grip and prevent slippage during use.

  5. Sterilization Compatibility: Open tendon strippers are made from high-quality surgical-grade stainless steel or other biocompatible materials that can withstand repeated sterilization cycles using methods such as autoclaving, gamma irradiation, or ethylene oxide (ETO) sterilization. This ensures that the instrument remains sterile and safe for use in the operating room environment.

  6. Single-Use vs. Reusable: Some open tendon strippers are intended for single-use only and are disposed of after each procedure to reduce the risk of cross-contamination and infection. Other instruments may be designed for multiple uses, provided they are properly cleaned, sterilized, and maintained according to manufacturer guidelines.

  7. Visibility: In open surgical approaches, visibility and access to the surgical site are not as limited as in minimally invasive procedures. Therefore, open tendon strippers may not require specialized features for visualization. However, the instrument should still be designed to provide clear visibility and precise manipulation within the surgical field.

  8. Specialized Tips: Depending on the specific surgical technique and anatomical considerations, open tendon strippers may have specialized tips or modifications to optimize tendon manipulation and extraction. These may include serrated edges, hooks, or fenestrations designed to enhance tissue engagement and extraction efficiency.

View Complete details

get quote request a call back

Surgical Shoulder Anchor

Rs 2,500  / PieceGet Best Price

Surgical Shoulder Anchor
Safex Inc surgical shoulder anchor, also known simply as a shoulder anchor, is a medical device used in orthopedic surgery, particularly in procedures involving the repair of damaged or torn soft tissues within the shoulder joint, such as the rotator cuff or labrum. Shoulder anchors are used to secure sutures to bone, providing fixation and stability for the repaired tissue. They are commonly employed in arthroscopic procedures, where minimally invasive techniques are used to access and operate within the shoulder joint.

Here are some key features and aspects of surgical shoulder anchors:

  1. Design: Shoulder anchors typically consist of a small implant made of biocompatible materials such as titanium, stainless steel, or bioabsorbable polymers. They are designed to be inserted into bone to provide a secure anchor point for sutures used in tissue repair.

  2. Variety of Types: There are various types of shoulder anchors available, each with unique designs and mechanisms of fixation. Common types include:

    • Screw-in Anchors: These anchors feature a threaded design that allows them to be screwed directly into bone, providing secure fixation.
    • Press-fit Anchors: These anchors are designed to be press-fitted into pre-drilled holes in bone, creating a snug fit without the need for screws.
    • Suture Anchors: These anchors have small holes or eyelets through which sutures can be passed, providing fixation by securing the sutures within bone.
  3. Suture Attachment: Shoulder anchors allow sutures to be attached directly to bone, providing a means of securing and tensioning repaired soft tissues. Sutures can be tied directly to the anchor or passed through eyelets or channels within the anchor.

  4. Size and Configuration: Shoulder anchors come in various sizes and configurations to accommodate different surgical techniques, patient anatomy, and repair requirements. They may vary in diameter, length, and shape to suit the specific needs of the surgical procedure.

  5. Arthroscopic Placement: Shoulder anchors are typically inserted into bone using specialized instruments and techniques during arthroscopic surgery. They are introduced through small incisions using cannulas and guided into position using fluoroscopic or arthroscopic imaging.

  6. Biomechanical Properties: Shoulder anchors are designed to provide secure fixation while minimizing the risk of damage to surrounding tissues or bone. They are engineered to withstand the forces exerted on repaired tissues during shoulder movement and rehabilitation.

  7. Biocompatibility: Shoulder anchors are made from materials that are biocompatible and compatible with the body's natural tissues. This helps to minimize the risk of adverse reactions or complications following implantation.